mastrad  logohome








CRACK MEASURING


See also DEMEC and

Digital Movement Gauge

Cracks occur in most buildings and civil engineering structures. Monitoring the changes in crack width is an important diagnostic technique for determining the cause and specifying the remedial work.

Crack Width Gauge

Crack Width Gauge

THE CRACK WIDTH GAUGE IS SPECIFICALLY DESIGNED TO ASSIST THOSE WHO SURVEY AND REPORT ON DAMAGED BUILDINGS

  • Quick and easy measurement.
  • Supplied in an ever ready case.
  • Manufactured in rigid durable acrylic.
  • Calibrated to edge scale which simplifies crack measurement in corners and awkward locations.

  • Tell-Tale Crack Monitor

    Tell-Tale Crack Monitor

  • Internal or external use
  • Monitors the opening or closing of a crack to an accuracy of 1.00mm
  • Capable of monitoring vertical as well as horizontal movements.
  • Crack record cards supplied with each Tell-Tale simplifies monitoring.

  •  Tell-Tale Plus Crack Monitor

    Tell-Tale PLUS Crack Monitor

    • Internal or external use.
    • Monitors the opening or closing of a crack to an accuracy of 1.0mm.
    • Capable of monitoring vertical as well as horizontal movement.
    • Crack record cards supplied with each Tell-Tale simplifies Monitoring.
    • PLUS
    • Monitoring Spigots incorporated in the Tell-Tale enable exact measurements to �0.1mm with calipers (see below)
    • Increased horizontal monitoring range to �25mm.
    • Manufactured in vandal resistant polycarbonate.
    • Fixing slots and "extra grip" surface.


    Tell-Tale Adaptor

    Corner Tell-Tale Plus

    MONITORS CRACKS IN CORNERS
    USE SINGLY TO MONITOR TWO DIMENSIONAL MOVEMENT
    USE IN PAIRS TO MONITOR THREE DIMENSIONAL MOVEMENR
    MAY BE USED IN INTERNAL OR EXTERNAL CORNERS
    THE TEL-TALE IS HINGED ENABLING IT TO BE USED IN INTERNAL CORNERS WITH ANGLES FROM 70 TO 180 DEGREES


    Digital Electronic Caliper

    Digital Electronic Caliper

  • Calibrated to 0.01mm and 0.0005ins
  • Caliper can be set at zero at any position
  • Fully portable.
  • Operating temperature range 0�C to 40�C
  • Vernier Caliper

    Vernier Caliper

    Calibrated to 0.02mm and 0.001ins
    Dial Caliper

    Dial Caliper

    Calibrated to 0.05mm
    Each Caliper is Supplied in a Plastic Case

    Each Caliper is Supplied in a Plastic Case

  • 100 6.3mm diameter stainless steel monitoring discs
  • 10 Avonmarks
  • 1 pack of plastic padding
  • Crack record cards to simplify monitoring
  • Digital and Dial calipers supplied in hard durable case
  • Crack width gauge